Technische Daten
Variante auswählen:
Overview
-
Product name:
D1 500 Air Unit: D1 500 Air Unit: D1 500 Air
D1 1000 Air Unit: D1 1000 Air
RFi Softbox 2x3' Unit: RFi Softbox 2x3' Unit -
Popular applications
D1 500 Air Unit: D1 500 Air Unit: Portrait, Still life
D1 1000 Air Unit: Portrait, Still life
RFi Softbox 2x3' Unit: Portrait, Still life -
Recommended for
D1 500 Air Unit: D1 500 Air Unit: Studio photography
D1 1000 Air Unit: Studio photography
RFi Softbox 2x3' Unit: Main light, Fill light, Rim light
Flash
-
Max energy
D1 500 Air Unit: 500 Ws
D1 1000 Air Unit: 1,000 Ws -
Energy range
D1 500 Air Unit: 7 f-stops (7.8 - 500 Ws)
D1 1000 Air Unit: 7 f-stops (15.6-1,000 Ws) -
Energy control increments
D1 500 Air Unit: 1/10 and full f-stops
D1 1000 Air Unit: 1/10 and full f-stops -
Recycling time
D1 500 Air Unit: 0.2 - 0.95 s
D1 1000 Air Unit: 0.2-2 s -
Energy stability
D1 500 Air Unit: ±1/20 f-stop
D1 1000 Air Unit: ±1/20 f-stop -
Flash duration t0.5
D1 500 Air Unit: 1/2,600 s (max power), 1/1,000 s (min power)
D1 1000 Air Unit: 1/1,800 s (max power), 1/700 s (min power) -
F-stop @ 2m / 100 ISO
D1 500 Air Unit: 45 4/5 with Magnum Reflector
D1 1000 Air Unit: 64 4/5 with Magnum Reflector -
TTL
D1 500 Air Unit: Nein
D1 1000 Air Unit: Nein -
HSS
D1 500 Air Unit: Nein
D1 1000 Air Unit: Nein
Continuous light
-
Max power
D1 500 Air Unit: 300 W
D1 1000 Air Unit: 300 W -
Selectable settings
D1 500 Air Unit: On, Off, Prop, Free
D1 1000 Air Unit: On, Off, Prop, Free
Wireless connectivity
-
Operating range
D1 500 Air Unit: Up to 300 m (1,000 ft)
D1 1000 Air Unit: Up to 300 m (1,000 ft)
Connectors
-
Sync
D1 500 Air Unit: 1
D1 1000 Air Unit: 1 -
Wire sync voltage
D1 500 Air Unit: Compliant to ISO 10330 standard
D1 1000 Air Unit: Compliant to ISO 10330 standard -
Wire sync connector
D1 500 Air Unit: 3.5 mm Mini-Phono
D1 1000 Air Unit: 3.5 mm Mini-Phono
Powering
-
Mains fuse requirement
D1 500 Air Unit: Slow blow 6 A / 230 V, 10 A / 120 V
D1 1000 Air Unit: Slow blow 6 A / 230 V, 10 A / 120 V -
Input power supply
D1 500 Air Unit: 100-127 V / 200-240 V, 50/60 Hz (nominal)
D1 1000 Air Unit: 100-127 V / 200-240 V, 50/60 Hz (nominal)
Other
-
Fan cooling
D1 500 Air Unit: Ja
D1 1000 Air Unit: Ja -
Ready signals
D1 500 Air Unit: Ja
D1 1000 Air Unit: Ja -
Auto dumping
D1 500 Air Unit: Ja
D1 1000 Air Unit: Ja -
Digital display
D1 500 Air Unit: Yes, f-stops and Air channels/groups
D1 1000 Air Unit: Yes, f-stops and Air channels/groups -
Photocell/IR-slave
D1 500 Air Unit: Ja
D1 1000 Air Unit: Ja
Measurements
-
Width
D1 500 Air Unit: D1 500 Air Unit: 13 cm / 5.12 in
D1 1000 Air Unit: 13 cm / 5.12 in
RFi Softbox 2x3' Unit: 60 cm / 24 in -
Length
D1 500 Air Unit: D1 500 Air Unit: 30 cm / 11.8 in
D1 1000 Air Unit: 30 cm / 11.8 in
RFi Softbox 2x3' Unit: 90 cm / 36 in -
Height
D1 500 Air Unit: 17 cm / 6.7 in
D1 1000 Air Unit: 17 cm / 6.7 in -
Weight
D1 500 Air Unit: D1 500 Air Unit: 2.44 kg / 5.38 lbs
D1 1000 Air Unit: 2.94 kg / 6.48 lbs
RFi Softbox 2x3' Unit: 1.5 kg / 3.3 lbs